Fire Ignition Device
Release time:2021-03-16 15:36 Popularity:
Usage
The fire Ignition device can ignite the vented combustible and harmful gas to eliminate its harm to the environment and safety. It is the treatment device and safety and environmental protection equipment for the tail gas and vented natural gas in the refinery and natural gas gathering and transmission station. In addition to being used in oil refineries and gas transmission stations, the device is often used with drilling fluid gas separator, which has been widely used in oil drilling engineering.
Features
1> Ignition voltage is 16Kv, ignition frequency is 100-1000 times / min, which can be controlled remotely;
2> The ignition end is made of 2520 high temperature resistant alloy, which has the characteristics of reliable ignition and long service life;
3> Simple design structure and convenient installation.
Technical Parameter
Model
|
Diameter
|
Charging Voltage
|
Ignition Voltage
(kV)
|
Ignition Medium
|
Ignition Frequency
|
Weight
(kgs)
|
Dimension
(mm)
|
GLYD200
|
DN200/8"
|
220V/50HZ
|
16
|
LPG/LNG/CNG
|
100-1000
|
500
|
650×1230×3200
|
Related videos: